EN/CN

Product

S2155G

Characteristic

●Free of constituents such as halogen, antimony, red phosphorous, ect.
No toxic gas emission and no hazardous residue during waste combustion.
● Excellent tracking resistance,CTI≥600V
● Excellent mechanical process ability, lower wearing of drill bit and punching die.

Application Area

● Home electrical appliance, OA equipment, power base board, apparatus and instrument, game machine, and etc.
  • Product Performance
  • Product Certificate
  • Data Download
Items Method Condition Unit Typical Value
Tg IPC-TM-650 2.4.25 DSC 130
Td IPC-TM-650 2.4.24.6 5% wt. loss 335
CTE (Z-axis) IPC-TM-650 2.4.24 Before Tg ppm/℃ 60
After Tg ppm/℃ 330
50-260℃ % 4.8
T260 IPC-TM-650 2.4.24.1 TMA min 60
Thermal Stress IPC-TM-650 2.4.13.1 288℃, solder dip s >50
Volume Resistivity IPC-TM-650 2.5.17.1 After moisture resistance MΩ.cm 1.2 x 108
E-24/125 MΩ.cm 2.8 x 106
Surface Resistivity IPC-TM-650 2.5.17.1 After moisture resistance 5.2 x 107
E-24/125 5.0 x 106
Arc Resistance IPC-TM-650 2.5.1 D-48/50+D-4/23 s 160
Dielectric Breakdown IPC-TM-650 2.5.6 D-48/50+D-4/23 kV >45
Dissipation Constant (Dk) IPC-TM-650 2.5.5.9 1MHz -- 4.8
Dissipation Factor (Df) IPC-TM-650 2.5.5.9 1MHz -- 0.011
Peel Strength (1Oz HTE copper foil)
IPC-TM-650 2.4.8
After thermal Stress 288℃,10s N/mm 1.6 [9.14]
Flexural Strength LW IPC-TM-650 2.4.4 A MPa 410
CW IPC-TM-650 2.4.4 A MPa 300
Water Absorption IPC-TM-650 2.6.2.1 E-1/105+D-24/23 % 0.15
CTI IEC60112 A Rating PLC 0
Flammability UL94 C-48/23/50 Rating V-0
E-24/125 Rating V-0

Remarks:

1. Specification sheet: IPC-4101/14 , is for your reference only.

2. All the typical value is based on the 1.6mm specimen.

3. All the typical values listed above are for your reference only and not intended for specification. Please contact Shengyi Technology Co., Ltd. for detailed information. All rights from this data sheet are reserved by Shengyi Technology Co., Ltd.

Explanation:C=Humidity conditioning, D=Immersion conditioning in distilled water,E=Temperature conditioning

The first digit following the letter indicates the duration of preconditioning in hours, the second digit the preconditioning temperature in ℃ and the third digit the relative humidity.